HiTrap Capto S, Cytiva, 17-5441-23, pack of 5 x 5 mL

Code: GE17-5441-23 D2-231

Analysis Note

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Application

Capto S has a stro...


read more

Your Price
€414.10 EACH
€509.34 inc. VAT

Analysis Note

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Application

Capto S has a strong sulfoethyl cation exchanger coupled to a chemically modified, high-fLow Agarose matrix. The modified Agarose matrix provides greater particle rigidity without compromising pore size, which allows more flexibility in process-scale applications. High dynamic binding capacity is achieved with a Dextran surface extender that coats the Agarose matrix.

Features and Benefits

High-throughput medium for capture and intermediate purification, excellent choice for process-scale purification. The combined properties of high binding capacity, high flow rate, and Low back pressure reduces process cycle times and improves productivity at process scale. Rigid Agarose matrix enables high bed heights and purification of viscous samples at high flow rates. Strong sulfoethyl(S) cation exchanger.

General description

HiTrap® Capto S is a strong cation exchanger prepacked with BioProcess Capto media for screening and small-scale protein purifications using ion exchange chromatography (IEX).

Legal Information

Capto is a trademark of Cytiva

HiTrap is a registered trademark of Cytiva

Storage and Stability

Store at 4 to 30 °C (0.2 M sodium acetate in 20% ethanol)

Store at 4 to 30 °C (20% Ethanol + 0.2 M Sodium Acetate)

average diameter90 µm (d50v)
bed size16 mm × 25 mm
bed volume5 mL
cleaning3-14
column I.D.16 mm
descriptionIon Exchanger Type (value)
manufacturer/tradenameCytiva 17-5441-23
matrixhighly cross-linked agarose with dextran surface extender
packagingpack of 5 × 5 mL
parameter42 psi, ﹤20 mL/min flow rate (The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.)
shelf lifePlease be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
suitabilitysuitable for bioprocess medium
working range4-13
Hazard Class3
Un Number1170
Pack GroupIII
This product has met the following criteria to qualify for the following awards:



PROCEED TO CHECKOUT

HAVE AN ACCOUNT? LOGIN


GUEST CHECKOUT

Proceed as a guest. You will have the option to register to access exclusive pricing and stock availability features after checkout.